An Alternative Method to Identify the Susceptibility Threshold Level of Device under Test in a Reverberation Chamber
By counting the number of pass/fail occurrences of a DUT (Device under Test) in the stirring process in a reverberation chamber (RC), the threshold electric field (E-field) level can be well estimated without tuning the input power and repeating the whole testing many times. The Monte-Carlo method is used to verify the results. Estimated values and uncertainties are given for Rayleigh distributed fields and for Rice distributed fields with different K-factors.